Refine your search:     
Report No.
 - 
Search Results: Records 1-20 displayed on this page of 44

Presentation/Publication Type

Initialising ...

Refine

Journal/Book Title

Initialising ...

Meeting title

Initialising ...

First Author

Initialising ...

Keyword

Initialising ...

Language

Initialising ...

Publication Year

Initialising ...

Held year of conference

Initialising ...

Save select records

Journal Articles

Operation status of the J-PARC high-intensity RF-driven negative hydrogen ion source

Shinto, Katsuhiro; Okoshi, Kiyonori; Shibata, Takanori*; Nammo, Kesao*; Kawai, Isao*; Ikegami, Kiyoshi*; Ueno, Akira

Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.928 - 931, 2023/11

J-PARC initiated the operation of the high-intensity rf-driven negative hydrogen (H$$^-$$) ion source in 2014 autumn. The ion source produces the H$$^-$$ beam with the beam current of 60 mA and the beam energy of 50 keV in order to inject the H$$^-$$ beam into the 3 GeV RCS with the beam current of 50 mA and the beam energy of 400 MeV from the J-PARC linac. We have achieved the longest continuous operation time of 4001 hours in the previous (2021/2022) campaign. The 2022/2023 campaign was the first time that the continuous operation of the H$$^-$$ ion source without any exchanges of the ion source until the end of the campaign was examined. We present the operation status of the J-PARC H$$^-$$ ion source in this campaign as well as the status of the J-PARC-made internal antenna test.

Journal Articles

Design of a matching circuit for a high-intensity negative hydrogen ion source driving with 324 MHz RF power source

Shinto, Katsuhiro; Shibata, Takanori*; Wada, Motoi*

Proceedings of 20th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.392 - 395, 2023/11

Negative hydrogen (H$$^-$$) ion sources which are used at high-intensity proton accelerator facilities such as J-PARC or neutral beam injection system for plasma heating in the fusion devices such as ITER produce plasmas by using RF sources driving with the frequency of 1-2 MHz. We have shown that the H$$^-$$ beams extracted from the RF-driven H$$^-$$ ion source with the frequency of several MHz have some fluctuations with the frequency of the fundamental and second harmonics. The reason is that the high plasma density is produced in the ion source with the low driving frequency. Therefore, we propose the driving RF frequency same as the RF sources with that of 324 MHz in the J-PARC linac, which is much higher than the ion plasma frequency, is used for producing the plasma to suppress the H$$^-$$ beam fluctuations. As a first step, we performed a design of a matching circuit for the higher frequency driven H$$^-$$ ion source. We present the background for decision of a new RF amplifier with much higher frequency and the design results.

Journal Articles

Outgassing characteristics from the J-PARC-made internal antenna for a high-intensity radio-frequency H$$^-$$ ion source

Shinto, Katsuhiro; Shibata, Takanori*; Okoshi, Kiyonori; Nammo, Kesao*; Ikegami, Kiyoshi*; Oguri, Hidetomo

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.675 - 679, 2023/01

In J-PARC, we have been conducting the test of a J-PARC-made internal antenna in order to establish the production method and understand the beam characteristics of the antenna. At this time, we investigated the outgas characteristics during the production of a high-density plasma by using the J-PARC-made antenna. It is confirmed that no remarkable impurities are emitted from the antenna by a residual gas analysis using a quadrupole mass analyzer installed downstream the ion source and a spectroscopic analysis of the plasma in the ion source. It is found that the emittances of the H$$^-$$ beam extracted from the J-PARC radio-frequency H$$^-$$ ion source by using the antenna was similar as those in case by using SNS antenna.

Journal Articles

Evaluation of RF antenna lifetime after long-term operation of J-PARC ion source

Shibata, Takanori*; Ishida, Masaki*; Nammo, Kesao*; Ikegami, Kiyoshi*; Okoshi, Kiyonori; Shinto, Katsuhiro; Oguri, Hidetomo

Proceedings of 19th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.863 - 867, 2023/01

Continuous operation duration of the J-PARC Radio Frequency (RF) ion source has been extended step by step these years for the goal to supply stable beam during the entire period of J-PARC user operation (around 7 months) each year. A 3651 hours (5 months) continuous ion source operation has been achieved from Nov. 2020 to Apr. 2021. As the lifetime of the ion source is mainly limited by failure on the RF antenna coil, detailed evaluation of the antenna surface condition is required to ensure the feasibility of the further extension of the operation time. In the present study, dimension measurements and SEM/EDS analyses were applied to understand the surface discoloration of the RF antenna. The discoloration after the long-term continuous operation is due to deposition of injected cesium (for H$$^-$$ surface production process) and of stainless used steel (Fe, Cr, Ni) from the ion source components sputtered by plasma. The results show that the enamel coating of the RF antenna has not worn out in the long-term continuous operation for several months and, hence, extension of the ion source continuous operation duration can be extended.

Journal Articles

Impurities reduction conditionings to recover best beam quality of J-PARC cesiated RF-driven H$$^{-}$$ ion source with new parts exposed to plasma

Ueno, Akira; Okoshi, Kiyonori; Ikegami, Kiyoshi*; Oguri, Hidetomo

Journal of Physics; Conference Series, 2244, p.012029_1 - 012029_5, 2022/04

 Times Cited Count:0 Percentile:0.32(Engineering, Electrical & Electronic)

The J-PARC cesiated RF-driven H$$^{-}$$ ion source is stably suppling about 58 mA beam with a duty factor of 1.25 % (0.5 ms$$times$$25 Hz) for the J-PARC LINAC 50 mA operations. For them, only three plasma chambers (PCHs) of #7, #8 and #9PCHs among ten PCHs have been used since the transverse emittances are more superior than others for unknown reasons. However, the emittances were enlarged by 16 % with the #7PCH, in which the plasma electrode (PE) temperature control plate (PETCP) was replaced to brand-new one to solve the air leak at the VCR vacuum fitting. The impurities from the new parts exposed to the plasma seemed to cause the degradation. The beam with almost the best emittances was reproduced by #4PCH with a new PETCP, in which sapphire tubes were used instead of the 99.7 % alumina ceramics tubes, after a new 2-MHz RF power scanning impurities reduction conditioning for 48 hours.

Journal Articles

Negative hydrogen ion sources for particle accelerators; Sustainability issues and recent improvements in long-term operations

Welton, R.*; Bollinger, D.*; Dehnel, M.*; Draganic, I.*; Faircloth, D.*; Han, B.*; Lettry, J.*; Stockli, M.*; Tarvainen, O.*; Ueno, Akira

Journal of Physics; Conference Series, 2244, p.012045_1 - 012045_13, 2022/04

 Times Cited Count:2 Percentile:89.37(Engineering, Electrical & Electronic)

High brightness, negative hydrogen ion sources are used extensively in many scientific facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings. Several facilities now have long-term ($$>$$ several years) experience with operating a variety of these sources (RF, filament, magnetron and penning) and have encountered, and in some cases solved, performance limiting issues. A representative list of such facilities includes, the US Spallation Neutron Source (SNS), Japan Proton Accelerator Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), CERN LINAC-4 and numerous installations of D-Pace ion sources. This report summarizes key ion source sustainability issues encountered at these facilities and discusses how some of them are being addressed through recent source improvements.

Journal Articles

Soundness evaluation of J-PARC RF ion source after 5-month continuous operation

Shibata, Takanori*; Okoshi, Kiyonori; Shinto, Katsuhiro; Nammo, Kesao*; Ikegami, Kiyoshi*; Oguri, Hidetomo

Journal of Physics; Conference Series, 2244, p.012041_1 - 012041_5, 2022/04

 Times Cited Count:1 Percentile:0.32(Engineering, Electrical & Electronic)

In the J-PARC user operation from Nov. 2020 - Apr. 2021, continuous operation of J-PARC Radio Frequency (RF) negative hydrogen ion (H$$^-$$) source up to 3,651 hours (5 months) has been achieved. The ion source was operated with the output H$$^-$$ current of 60 mA, the duty factor (for plasma generation) 2% and the input RF power up to 30 kW. After the operation, phase space diagrams at the Radio Frequency Quadrupole (RFQ) entrance were measured by the emittance monitor at the ion source test stand (IS-TS) under the same operation condition as in the J-PARC Linac. Comparison of the phase spaces and the beam emittances between the ion sources in the present and the previous operations shows slight difference. From the direct observation of the antenna coil, no exhaustion or the decrease in the thickness of the enamel coating of the coil have been confirmed. The results indicate the possibility of the next goal of the long-run up to 7 months, which is the same as the full duration of the J-PARC user operation in 1 year.

Journal Articles

Effect of a 2-MHz RF source on the H$$^-$$ beam extracted from an RF-driven high-intensity H$$^-$$ ion source

Shinto, Katsuhiro; Shibata, Takanori*; Wada, Motoi*

Proceedings of 18th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.230 - 233, 2021/10

In most proton accelerator facilities such as J-PARC, SNS, CERN, a H$$^-$$ ion source equipped with a 2-MHz rf driver for plasma generation produces H$$^-$$ beams. We have reported H$$^-$$ beam characteristics extracted from the J-PARC rf-driven high-intensity H$$^-$$ ion source. We have been developing an emittance measurement apparatus equipped with a highly time-resolved data acquisition system in order to observe fluctuation of the beam emittance in association with the frequency of the rf driver. By using this apparatus, we found that the beam emittance is fluctuated with the frequency with the rf driver and higher harmonics. We will show some obtained results of the emittance fluctuation.

Journal Articles

Synchronization system of ion source RF and cavity RF in J-PARC linac

Shibata, Takanori*; Hirano, Koichiro; Hirane, Tatsuya*; Shinto, Katsuhiro; Hayashi, Naoki; Oguri, Hidetomo

Proceedings of 18th Annual Meeting of Particle Accelerator Society of Japan (Internet), p.417 - 421, 2021/10

In J-PARC linac, the operation of an rf-driven high-intensity H$$^-$$ ion source was initiated in 2014. For plasma ignition, the 2-MHz rf amplifier outputs the power of several tens kW. However the rf amplifier for the ion source and those for the accelerating cavities have not been synchronized. As a result, the wave hights in the beam waveforms were different in shot by shot. Therefore, we have developed an synchronization system between the rf system for the ion source and those for the cavity systems and succeeded the same wave hights in the waveforms.

Journal Articles

High-speed emittance measurements for beams extracted from J-PARC RF ion source

Shibata, Takanori*; Shinto, Katsuhiro; Wada, Motoi*; Oguri, Hidetomo; Ikegami, Kiyoshi*; Okoshi, Kiyonori; Nammo, Kesao*

AIP Conference Proceedings 2373, p.050002_1 - 050002_9, 2021/08

Oscillation of emittance and Twiss parameters in the negative ion beam from the J-PARC 2-MHz RF ion source is measured by applications of a double-slit emittance monitor located at the RFQ (Radio Frequency Quadrupole) entrance. The emittance monitor is equipped with a newly-developed 60 MS/s data acquisition system, so that beam current oscillation in a few MHz can be observed with enough time resolution. From the measurement, it is shown that the beam phase space consists of (1) a DC component in the beam core, (2) a 2-MHz oscillating component which takes place both in the beam core and the halo and (3) a doubled RF frequency (4 MHz) oscillation which slightly exists in the beam halo. The major component is the 2-MHz component, which resultantly decides the beam emittance oscillation frequency. A typical value of the beam emittance in the present experiment is 0.34 $$pi$$ mm-mrad, while the amplitude of the 2 MHz oscillation is around 0.04 $$pi$$ mm-mrad. The results indicate that the high-frequency oscillation component occupying about ten-percent of the beam from the RF source travels a few meters passing through a magnetic lens focusing system.

Journal Articles

NIBS 2020 reference sheets

Sarmento, T.*; W$"u$nderlich, D.*; Fantz, U.*; Friedl, R.*; Rauner, D.*; Tsumori, Katsuyoshi*; Shenjin, L.*; Chen, W.*; Bollinger, D.*; Oguri, Hidetomo; et al.

AIP Conference Proceedings 2373, p.110001_1 - 110001_18, 2021/08

In preparation for NIBS 2020 various labs prepared reference sheets containing key information about their ion sources and the machines that they serve. The contents of the reference sheets have been formatted and edited into this paper for posterity and ease of access.

Journal Articles

Phase space formation of high intensity 60 and 80 mA H$$^-$$ beam with orifice in J-PARC front-end

Shibata, Takanori*; Ikegami, Kiyoshi*; Nammo, Kesao*; Liu, Y.*; Otani, Masashi*; Naito, Fujio*; Shinto, Katsuhiro; Okoshi, Kiyonori; Okabe, Kota; Kondo, Yasuhiro; et al.

JPS Conference Proceedings (Internet), 33, p.011010_1 - 011010_6, 2021/03

Together with the intensity upgrade in J-PARC Linac Front-End, improvement of RFQ transmission ratio is an important task. This RFQ transmission ratio depends strongly upon the solenoid current settings in the low energy beam transport line (LEBT). In the present study, high beam current cases (72 mA and 88 mA H$$^-$$ beam current in LEBT) are investigated at a test-stand. Phase space distributions of the H$$^-$$ beam particles at the RFQ entrance are measured and compared with numerical results by Particle-In-Cell simulation. As a result, it has been clarified that a 15 mm $$phi$$ orifice for differential pumping of H$$_2$$ gas coming from the ion source plays a role as a collimator in these beam conditions. This leads to change the beam emittance and Twiss parameters at the RFQ entrance. Especially in the condition with the beam current up to 88 mA in LEBT, the beam collimation contributes to optimize the phase space distribution to the RFQ acceptance with relatively low solenoid current settings. As a higher solenoid current setting would be necessary to suppress the beam expansion due to high space charge effect, these results suggest that current-saving of the solenoids can be possible even in the higher beam intensity operations.

Journal Articles

J-PARC H$$^{-}$$ ion source and space-charge neutralized LEBT for 100-mA high energy and high duty factor LINACs

Ueno, Akira

Review of Scientific Instruments, 91(3), p.033312_1 - 033312_9, 2020/03

 Times Cited Count:4 Percentile:28.61(Instruments & Instrumentation)

In July 2019, a 3 GeV 920 kW beam was accelerated for 10.5 hours in the J-PARC. During the operation, the H$$^{-}$$ ion source and LINAC was operated with the beam duty factor (BDF) of 1.25% (0.5 ms$$times$$25 Hz) and the ejected beam intensities of 58 and 50 mA, respectively. Separately, they were stably operated with the BDF of 1.5% (0.6 ms$$times$$25 Hz) and the ejected beam intensities of 72 and 60 mA, respectively. Based upon the 100-mA and BDF 5% (1 ms$$times$$50 Hz) H$$^{-}$$ ion source operation on a test-stand, the possibility of the 100-mA high energy and high duty factor LINACs with a radio frequency quadrupole LINAC with an injection energy higher than 64 keV is presented. The unexpectedly effective space-charge neutralization effects in the low energy beam transport are also presented. Furthermore, the transverse emittance improvements by about 8% with the shortest beam extractor are presented.

Journal Articles

Measurement of a time dependent spatial beam profile of an RF-driven H$$^-$$ ion source

Wada, Motoi*; Shinto, Katsuhiro; Shibata, Takanori*; Sasao, Mamiko*

Review of Scientific Instruments, 91(1), p.013330_1 - 013330_5, 2020/01

 Times Cited Count:3 Percentile:21.33(Instruments & Instrumentation)

The ions are extracted from an ion source through a plasma sheath where a low frequency electromagnetic induction drives transport of charged particles including the target ions. High frequency alternating current commonly excites plasmas in sources for negative hydrogen (H$$^-$$) ions at a frequency in the MHz range. A high-speed beam current monitor system coupled to a narrow entrance slit enabled the investigation of the special distribution of the AC component intensity of the H$$^-$$ ion beam extracted from an ion source driven by a 2 MHz radio frequency (RF) power. The distribution showed a smaller oscillation of the beam at the center.

Journal Articles

Progress of long-time operation and industrial use of negative ion source for particle accelerator

Oguri, Hidetomo

Purazuma, Kaku Yugo Gakkai-Shi, 95(7), p.340 - 344, 2019/07

no abstracts in English

Journal Articles

Numerical and experimental study of H$$^{-}$$ beam dynamics in J-PARC LEBT

Shibata, Takanori*; Ikegami, Kiyoshi*; Liu, Y.*; Miura, Akihiko; Naito, Fujio*; Nammo, Kesao*; Oguri, Hidetomo; Okoshi, Kiyonori; Otani, Masashi*; Shinto, Katsuhiro; et al.

Proceedings of 29th International Linear Accelerator Conference (LINAC 2018) (Internet), p.519 - 521, 2019/01

Transport process of negative hydrogen ion (H$$^{-}$$) in LEBT (Low Energy Beam Transport) is investigated by comparison of experimental and numerical results. A three dimensional Particle-In-Cell (PIC) particle transport model has been developed in order to take into account (i) axial magnetic field by two solenoids in J-PARC LEBT and (ii) radial electric field by space charge (SC) effect. Ratio of H$$^-$$ beam particles inside the RFQ (Radio Frequency Quadrupole) acceptance to the total particles at the RFQ entrance is calculated for different current conditions in LEBT solenoid 1 and 2. The results are compared with RFQ transmission rate measured in the J-PARC linac commissioning. The double peak of RFQ transmission rate to the solenoid applied current seen in the measurement is explained by the calculation results. The results indicate that presence of the LEBT orifice for differential pumping plays a role as a collimator to reduce emittance at RFQ entrance.

Journal Articles

Progress of the J-PARC cesiated rf-driven negative hydrogen ion source

Shinto, Katsuhiro; Okoshi, Kiyonori; Shibata, Takanori*; Nammo, Kesao*; Ikegami, Kiyoshi*; Takagi, Akira*; Namekawa, Yuya*; Ueno, Akira; Oguri, Hidetomo

AIP Conference Proceedings 2052, p.050002_1 - 050002_7, 2018/12

 Times Cited Count:6 Percentile:93.93(Physics, Applied)

In the 2017/2018 campaign, the J-PARC cesiated rf-driven negative hydrogen (H$$^-$$) ion source producing H$$^-$$ beam with the beam current of 47 mA accomplished three long-term operations more than 2,000 hours without any serious issues. On the final day of this campaign, the ion source produced an H$$^-$$ beam current of 72 mA so that the linac commissioning group could demonstrate the beam current of 60 mA at the linac exit. We are also conducting an endurance test of a J-PARC-made antenna at a test bench. The antenna achieved the operation time approximately 1,400 hours.

Journal Articles

Present status of the J-PARC cesiated rf-driven H$$^-$$ ion source

Shinto, Katsuhiro; Okoshi, Kiyonori; Ikegami, Kiyoshi*; Takagi, Akira*; Shibata, Takanori*; Nammo, Kesao*; Namekawa, Yuya*; Ueno, Akira; Oguri, Hidetomo

AIP Conference Proceedings 2011, p.050018_1 - 050018_3, 2018/09

 Times Cited Count:3 Percentile:82.15(Physics, Applied)

Journal Articles

Observation of beam current fluctuation extracted from an RF-driven H$$^-$$ ion source

Shinto, Katsuhiro; Shibata, Takanori*; Miura, Akihiko; Miyao, Tomoaki*; Wada, Motoi*

AIP Conference Proceedings 2011, p.080016_1 - 080016_3, 2018/09

 Times Cited Count:5 Percentile:91.75(Physics, Applied)

Journal Articles

Observation of plasma density oscillation with doubled value of RF frequency in J-PARC RF ion source

Shibata, Takanori*; Shinto, Katsuhiro; Takagi, Akira*; Oguri, Hidetomo; Ikegami, Kiyoshi*; Okoshi, Kiyonori; Nammo, Kesao*; Naito, Fujio*

AIP Conference Proceedings 2011, p.020008_1 - 020008_3, 2018/09

 Times Cited Count:5 Percentile:91.75(Physics, Applied)

44 (Records 1-20 displayed on this page)